Features
The tester is supplied in a protective case which can be worn on a belt or slung around the neck. The device facilitates the testing of blasting cables and is approved for use in fiery mines.
DME certificate of approval No. CT6
Operation
An electronic make or break circuit alternately makes a short and open-circuit at one end of the cable. If all is well a circuit Continuity Tester (CT-01) at the other end will flash on and off in rhythm with the Circuit Interrupter to indicate both continuity and absence of shorts in the blasting circuit.
The unit is powered by a replaceable PP39V Zinc Carbon battery and is capable of 400 hours of continuous use.